Project Description

FOSTER BRIDGE CRANE REHABILITATION AND RE-RATING

Project Details

  • Up-rating the 50-ton bridge crane to 60-ton
  • Structural modifications to the existing bridge
  • Replacement of cab, controls, lights, control wiring, and power wiring
  • Replacement of bridge drive motor, gearbox, and brake
  • Replacement of Crane Buss Bar
  • Removal of end trucks and refurbishment of end trucks
  • Inspection and service of remaining components and systems
  • Recertification to the 60-ton rating via acceptance and load testing

On this project, BCI was able to provide the Government with a new trolley instead of refurbishing the existing trolley (as contract called for) via a VECP with a $65k savings to the Government.

Specifications

CUSTOMER NAME

LOCATION

Foster Powerhouse, OR

Project Gallery